If you have COVID-19 symptoms, suspect you have been diagnosed, and are waiting for the results of a compulsory test, you may want to choose a rapid antigen test for the new coronavirus to test yourself. There are many brands on the marketRapid test kitWhen purchasing, please refer to the EU's common list of rapid antigen tests for the 2019 coronavirus. Gogo Herbs provides you with a detailed introduction of products that meet the standardsAbbott – Panbio™ Rapid COVID-19 Antigen Test, suitable for people of all ages, and results are available in 15 minutes.
What is the Abbott – Panbio™ Rapid Test?
Panbio™ COVID-19 Antigen Self-Test is a lateral flow immunoassay for the detection of coronavirus SARS-CoV-2 nucleocapsid protein antigens in middle turbinate swabs.
Abbott – Panbio™ Rapid Antigen Test for COVID-19 Certified
The product has obtained the EU CE certification, is listed in the EU Common List, and is approved by the World Health Organization (WHO EUL) as a rapid antigen test for asymptomatic people.
Abbott – Panbio™ Rapid Antigen Test for COVID-19 Origin/R&D Institution
This product is produced in Korea. Abbott has been committed to this cause for more than 130 years, ever since Chicago physician Dr. Wallace C. Abbott opened his pharmacy, and the mission remains the same today. Abbott has 107,000 dedicated and professional employees around the world, providing revolutionary medical care in different countries and regions, including Hong Kong. For more than 55 years, more than 200 employees have been dedicated to helping the people of Hong Kong enjoy their best life. The company's businesses in Hong Kong include cardiovascular, pharma, diagnostics, pharmaceuticals, informatics, molecular medicine, neuromodulation and nutrition. In addition, Abbott continues to explore innovative technologies and enhance treatments for some of the world's most complex diseases.
Abbott – Panbio™ Rapid COVID-19 Antigen Test Specifications
1 instruction booklet
1 test device
1 extraction tube
1 blue hijab
1 buffer bottle
1 swab
1 bag
1 test tube rack
Abbott – Panbio™ Rapid Antigen Test for COVID-4: Four Product Advantages
Test results in 15 minutes
Just follow the simple steps
Comfortable nasal swab sampling method – only inserted 2cm into the nasal cavity
Suitable for people of all ages (people under 14 years old need adult support)

Abbott – Panbio™ Rapid COVID-19 Antigen Test Accuracy
The Panbio™ COVID-19 Antigen Self-Test has been shown to correctly identify 98.1% of positive tests and 99.8% of negative tests in clinical evaluations performed by healthcare professionals. All specimens were confirmed positive and negative by RT-PCR test approved by the US FDA for emergency use.
In a clinical evaluation of 102 self-test users, the Panbio™ COVID-19 Antigen Self-Test correctly identified 100.0% of negative specimens and 95.2% of positive specimens. All specimens were confirmed positive and negative by Panbio™ COVID-19 Antigen Rapid Test Device (nasopharyngeal).
Abbott – Panbio™ Rapid Antigen Test for COVID-19 Applicable Population
Suitable for screening asymptomatic patients, those with symptoms within 7 days, and those who have been in contact with confirmed patients (people under 14 years old require adult support).
Abbott – Panbio™ COVID-4 Rapid Antigen Test XNUMX Steps to Use
- Nasal sampling, rotate the left and right nostrils 4-6 times each (about 15 seconds each)
- Prepare the sample, put the nasal stick into the antigen extraction tube, and mix it with the reagent in the tube
- To perform the test, close the blue lid, turn the test tube upside down vertically, and drop the test sample into the sample hole.
- Start timing, wait 15 minutes, and check the test results
Abbott – Panbio™ Rapid Antigen Test for COVID-19 Results Interpretation
Positive result: If you see both the Control (C) and Test (T) lines, it means COVID-19 was detected. (Please check carefully! As long as the test (T) line appears, no matter how subtle, it means the result is positive)
Negative result: If you only see the Control (C) line, it means no COVID-19 was detected.
Invalid Results (Test Ineffective): If the Control (C) line does not appear, the test is ineffective and invalid. This may be caused by incorrect testing procedures. Please test again.
Abbott – Panbio™ Rapid Antigen Test for COVID-19 Precautions
- For in vitro diagnostic use only.
- Please read the instructions before performing the test. Please follow all instructions for accurate results.
- Do not eat or smoke when handling samples.
- Wash hands thoroughly before and after testing.
- In case of spills, clean them up thoroughly with an appropriate disinfectant.
- Please place all specimens, cartridges, and potentially contaminated materials (ie, swabs, extraction tubes, test devices) in the bag provided.
- Use only the fluid from the buffer bottle provided with the test kit. Use of other fluids may result in inaccurate results.
- Keep the test kit out of the reach of children.
- To prevent contamination, touch only the sides of the test device and make sure the tip of the swab touches only the nasal cavity and inside the extraction tube.
- The swabs provided should only be used to collect nasal (middle turbinate) specimens.
- Each test device, swab, blue tip cap, buffer bottle and bag are single-use. Do not reuse individual contents. The swab holder is reusable.
- Do not dip the swab into buffer or other liquids before inserting it into the nasal cavity.
- The included buffer bottle contains <0.1% sodium azide as a preservative, which may be toxic if ingested. If the buffer solution comes into contact with eyes, rinse with running water for at least 15 minutes. If stinging sensation persists, seek medical attention immediately.
- If the test kit has been stored in the refrigerator, please let it sit at room temperature (15 to 30°C) for 30 minutes before use.
- Do not use the test kit if the bag is damaged or the seal is broken.
- The swab sample should be tested immediately after collection.
Abbott – Panbio™ Antigen Test Results
The test results are invalid, possibly because the test procedure was incorrect. Please wait 4 hours before repeating the test.
A positive test result means that proteins from the virus that causes COVID-19 were found in your nasal swab sample. You will most likely need to self-isolate at home to prevent the spread of COVID-19. A positive result does not exclude the possibility of co-infection with other pathogens. Please follow local social distancing guidelines to prevent the spread of the virus and contact your doctor or local health department immediately.
A negative test result means it is unlikely that you had COVID-19 at the time of the test. The test did not detect any antigens in your nasal sample, but the test can also give a false negative result. False negative test results can come from several factors:
• During infection, the amount of antigen in the swab sample may decrease over time.
• The test may come back negative before symptoms develop.
• Failure to perform the test as directed.
• Failure to properly collect, extract, or transport the specimen.
If symptoms persist, please test again after 1-2 days as the coronavirus may not be detected in the early stages of infection. We recommend that you continue to follow local self-isolation policies and consult your doctor.